Not one I've seen before. Trust no one, not even your helpers

top 18 comments
sorted by: hot top controversial new old
[–] reddig33@lemmy.world 27 points 2 months ago (1 children)

Someone must’ve been very tired that day. I’m not an electrician and even I know where the ground wire goes.

[–] shalafi@lemmy.world 2 points 2 months ago

I'm no electrician and I could tell what was wrong with a 2-second glance.

So what happens if it's wired like this?

[–] Brujones@lemmy.world 20 points 2 months ago

Wow. Just...wow.

[–] fubarx@lemmy.world 19 points 2 months ago (2 children)
[–] SharkEatingBreakfast@sopuli.xyz 6 points 2 months ago

You can touch this! ....but it might hurt.

[–] jasonwnclife@lemm.ee 9 points 2 months ago (3 children)

Clearly that is bad… but how bad? Like burn it down bad?

[–] Undearius@lemmy.ca 18 points 2 months ago* (last edited 2 months ago)

The metal on that light switch would be live any time the other light switch (on the other end of the red traveller wire) is turned on.

If that box is metal, it would make the metal brackets of the other switches live as well, and assuming one of the other switches is properly wired, it would just go back to the panel on the ground wire.

I think that would either complete the circuit and the device would turn on, or it would ground the circuit and pop the breaker. The same would likely happen with this switch as well considering the ground is wired on the hot terminal.

I'm also not an electrician so this is a full-on guess.

[–] kryptonianCodeMonkey@lemmy.world 8 points 2 months ago

Wiring hot directly to ground will create a short circuit. Ideally that causes the breaker to flip immediately enough to stop anything bad from happening as the amperage jumps. But it can melt wires, fry electronics/outlets/switches, cause sparks to fly, create a shock hazard, or start a fire, yes. The breaker is there to "ideally" prevent that, though they can fail. I'm also not an electrician by trade so I'm really not sure, but i wonder too if one could fuck up the wiring bad enough to cause a short in parallel to the breaker that doesn't even trip it. If old boy is sticking the ground wire into hot switches, I would question what other dumb shit he might have done.

[–] stupidcasey@lemmy.world 6 points 2 months ago

"attempted murder", now honestly what is that? Do they give A Nobel prize for attempted chemistry?

[–] lurch@sh.itjust.works 9 points 2 months ago (3 children)

Why is there even a bare wire? 🤔

[–] afk_strats@lemmy.world 26 points 2 months ago

Not an electrician or even electrical savvy but it's typical for ground wires to be bare. Its not typical or good or even sane for them to be connected to something which WILL carry electricity.

[–] Lucky_777@lemmy.world 16 points 2 months ago

Bare wire for grounding purposes. That's all it's used for.

[–] witty_username 13 points 2 months ago (1 children)

Usa (and probs some others) use a bare ground wire

[–] tarsn@lemmy.ca 12 points 2 months ago

Canada is the same

[–] nickwitha_k@lemmy.sdf.org 6 points 2 months ago (1 children)

Think maybe someone is red/green color blind?

[–] nik282000@lemmy.ca 10 points 2 months ago* (last edited 2 months ago)

Ground is bare in the US/Canada in residential wiring (insulated grounds are only found when pulling wire in conduit or in isolated ground systems like hospitals). Guy who did this is just an asshole and doesn't know how a 3-way switch works.

That breaker testing switch looks perfectly to code to me.